DMP Type DMP Electronic Motor Protection Relay (EMPR)
Characteristics 
Digital EMPR with Built-in Microprocessor Control Unit (MCU)
All models of EMPR, which have characteristics of perfect digital with built-in MCU, features excellent reliability by materializing real-time data processing & high precision.
Various Motor Protective Functions

DMP demonstrates excellent motor protective function by protecting motors against Over-current, Phase failure, Asymmetry, Lock, Reverse phase and Undercurrent. It has also option of ground fault or short circuit protection, as required.

Common Usage of Unified and Extension Types

The display unit can be detached from the main relay, if required, and can be fitted on to the MCC / Panel door to enable user verify various causes of faults, values of faults, and values of current without opening the door. Alternatively, it can also be installed inside the MCC / Panel as a complete assembly form.

Common Use of the Screw connection-type and Tunnel-type Terminals
The removable terminal base can be attached to various installation environments.
Indicates Cause and Values of Faults
While the cause and Values of Faults are indicated on the digital display, DMP also indicates load factors during operation. This function enables users to check the operating status of motor at all times.
DMP models have facility of 3-phase digital ampere-meter function
Selectable either Inverse time or definite time characteristics
User can select desired inverse or definite time characteristics depending upon the application and its requirement.
Applicable to Inverter Circuit
DMP performs well against high-frequency noise, and its applicable to inverter circuit.
The applicable frequency ranges from 20Hz to 200Hz.
Awarded "Good Design of 1999" Mark DMP was awarded "Good Design of 1999" Mark for its elegant appearance and excellent design.
Ratings - Items
  Description
  Operating Time Characteristics
  Selection of Definite or Inverse Time Characteristics
  Time Setting (Sec) time limit
  Inverse time
  Reset Time
  Manual Prompt Reset
  Installation Method
  Dual Installation Methods of Screw or Din-Rail mount
  Operating Voltage
  Output Relay Resistance Load (In case of the shortage model)
  ZCT Input (In case of the earth leakage)
  Operating Temperature
  Preserving Temperature
  Relative humidity 
Specification
  Unified type Separate type
  Adjusting Range of Current (A)
  Applicable Motor Capacity
  Terminal Type
  Tunnel Type
Earth Leakage Protection
  Unified type Separate type
  Adjusting Range of Current (A)
  Applicable Motor Capacity
  Terminal Type
  Tunnel Type
*It is possible to set the earth leakage sensitivity current between 100mA and 2500mA. (*CS-LG ZCT model must be used for this function.) 
Shortage Protection
  Unified type Separate type
  Adjusting Range of Current (A)
  Applicable Motor Capacity
  Terminal Type
  Tunnel Type
* It is possible to set the instantaneous short circuit current between 30% and 1800%. 
Standards
DMP Series EMPR conforms to IEC60947 and IEC1000-4
Approval and Certification
DMP Model approved from UL/CSA and CE marked
back